The short version
- Which setting
- The radiator (heating) dial or menu, not the tap one
- Combi in winter
- 60°C, then try 55°C if the house stays warm
- Milder months
- 50–55°C
- Hot water cylinder
- Keep stored water at 60°C or above
- Typical saving
- About £23–£68 a year at today's gas price
- Time it takes
- A couple of minutes, plus a week to test
Your boiler has three different temperatures
Most of the confusion about boiler settings comes from mixing up three separate numbers. They do different jobs, and only one of them is the “flow temperature” people mean.
Flow temperature (heating)
Radiator symbol
How hot the boiler makes the water it pumps round your radiators. This is the one to turn down. It's often set to 70–80°C out of the box.
Hot water temperature
Tap symbol
How hot the water is at your taps and shower. On a combi it's a separate setting. On a system or regular boiler it's how hot the cylinder is kept.
Room thermostat
On the wall or an app
How warm you want the room to be. The boiler fires until the room reaches it, then stops. Changing it changes how warm your home is.
A useful way to picture it: the thermostat is where you want to get to, and the flow temperature is how hard the boiler pushes to get you there. Lowering the flow temperature is like easing off the accelerator. You still arrive, a bit later, using less fuel.
The thermostat is a separate saving. Turning it down a degree also cuts your bill, but it does that by keeping your home cooler. Our winter energy-saving tips cover that one, along with the other quick wins.
Why a lower flow temperature is more efficient
Almost every gas boiler fitted in the UK in the last twenty years is a condensing boiler. When it burns gas, the exhaust contains water vapour carrying a lot of heat. A condensing boiler is designed to cool that exhaust enough for the vapour to turn back into liquid. That gives up extra heat, which goes back into your heating instead of out of the flue.
It only works if the water coming back from the radiators (the “return”) is cool enough, roughly below 55°C. If the flow is set at 80°C, the return comes back too hot, the vapour doesn't condense, and the boiler runs like an old non-condensing model. Which? and EDF both make the same point: at 75–80°C most combis are too hot to work at their best, and around 60°C keeps them in condensing mode.
Lab testing backs it up. In tests for Nesta at the University of Salford's Energy House, a real terraced house built inside a climate chamber, dropping the flow from 80°C to about 60°C in winter conditions cut the gas used for heating by 12%. The trade-offs were real but small: the morning heat-up took 37 minutes instead of 23, and the living room settled at 20.3°C instead of 21.0°C.
| Winter flow setting | Heating gas vs 80°C | Morning heat-up | Living room held at |
|---|---|---|---|
| 80°C | Baseline | 23 min | 21.0°C |
| 70°C | −5% | 30 min | 20.7°C |
| 60°C | −12% | 37 min | 20.3°C |
| 55°C | −16% | 56 min | 20.0°C |
| 48°C | −23% | 157 min | 19.6°C |
Salford Energy House winter tests for Nesta, October 2022 (one house, controlled conditions). Heating gas only, excluding hot water. Your home will differ.
The table shows why 60°C is the usual advice rather than 48°C. Going very low saves more gas, but the house took over two and a half hours to warm up in the morning. Around 55–60°C is where most homes get most of the saving without noticing much difference.
What to set it to
The right number depends on what kind of boiler you have. Here's a starting point for each. If you don't know your boiler type: a combi heats water instantly when you turn on a tap and has no hot water tank. A system or regular boiler heats a hot water cylinder, usually in an airing cupboard.
| Your setup | Heating (radiator) setting | Hot water setting |
|---|---|---|
| Combi boiler, winter | 60°C, try 55°C | Low enough that you don't add cold water. Octopus suggests 55°C |
| Combi boiler, spring and autumn | 50–55°C | As above |
| System or regular boiler with a cylinder | 60°C or a little below for radiators | Cylinder must reach 60°C or above (HSE Legionella guidance) |
| Heat pump | Leave to your installer | Leave to your installer |
Combi boilers. Nesta's advice is to change with the seasons: 60°C in winter, 55°C in early spring and late autumn, and 50°C or below in mild weather if you're comfortable. Octopus tells its customers 55–60°C. If your boiler has a pre-heat or “comfort” mode that keeps water warm all day so the tap runs hot instantly, Which? suggests turning that off too. You'll wait a few seconds longer for hot water and save the gas spent keeping it warm.
Boilers with a hot water cylinder. You can usually still lower the radiator setting. The stored water is the thing to watch. The Health and Safety Executive says Legionella bacteria multiply between 20°C and 45°C and don't survive above 60°C, so hot water cylinders should store water at 60°C or higher. On many system and regular boilers the same flow heats both the radiators and the cylinder. If you turn it right down, the cylinder may never get hot enough. Check the thermostat on the cylinder itself (usually a small dial on the side), keep it at 60°C, and ask your engineer at the next service whether your heating and hot water can be set separately.
Heat pumps are a different machine. They already run at low flow temperatures, typically set during installation and often adjusted automatically with the weather. Don't apply boiler advice to a heat pump. Our heat pump guide covers running costs and the tariffs built for them.
How to change it
Every manufacturer does it slightly differently, but the process is the same. You only ever touch the controls on the outside of the boiler that are meant for you.
- 1
Find the controls
Look at the front panel. Some boilers have two dials, some have buttons and a small screen. A few hide the controls behind a flap that hinges or slides down. That flap is fine to open. The screwed-on casing is not.
- 2
Find the radiator setting
Look for a radiator symbol (a rectangle with wavy lines or fins). The tap symbol is the hot water setting. Leave that one for now.
- 3
Note where it's set now
Take a photo of the dial or screen before you change anything, so you can put it back.
- 4
Turn it down to 60°C
On a dial without numbers, the markings usually run low to high. The manual will say which mark is around 60°C. On a screen, press the radiator button and use + and − until it reads 60.
- 5
Not sure? Check the manual
Search the make and model printed on the front of the boiler with "manual". Nesta's free Money Saving Boiler Challenge tool also walks you through many common models step by step.
- 6
If there's no visible setting
Some boilers are controlled by a smart thermostat or app, which may have its own flow setting. If you still can't find it, ask a Gas Safe engineer at your next service. Don't open the boiler.
Test it for a week
The aim is the lowest setting at which your home still reaches the temperature on your thermostat in a sensible time. A week is enough to know.
- Leave the thermostat alone. If you turn the flow down and the thermostat up at the same time, you'll cancel out the saving and won't learn anything.
- Expect radiators to feel cooler to the touch. That's normal. They're running warm rather than scorching, for longer. What matters is whether the room gets warm.
- Start the heating a little earlier. If your timer brings the heating on at 6.30am, try 6.15am. Nesta's tests found that a lower flow with a longer warm-up still used less gas than a high flow for a shorter time.
- Watch the coldest room. If one room never gets warm, the radiator may be too small for a low flow temperature. Bleed it first (cold patches at the top mean trapped air), then turn the flow back up 5°C if it's still cold.
- If all is well after a week, try 5°C lower. Stop at the point where the house no longer keeps up.
- Check a smart meter display if you have one. Compare gas use on days with similar weather before and after. Our smart meter guide explains how to read it.
What it saves at this winter's gas price
Estimates vary because homes vary. A house that already ran at 65°C has less to gain than one at 80°C, and a well-insulated flat uses less gas to begin with. The published figures range from a few per cent to 9% of total gas use:
- Nesta's 2022 tests with Salford found 9% of total gas use for 80°C to 60°C (12% of heating gas alone).
- The Heating and Hot Water Industry Council's estimate, quoted by Octopus, is around 6–8%.
- Some advice sites use a more cautious figure of around 3% of the bill, which allows for homes that were already set lower.
Here's what that range means for a typical home using 9,500 kWh of gas a year (Ofgem's current typical figure). The saving is on the gas you burn, so it's worked out on the unit rate only. The standing charge doesn't change.
| Saving | Gas saved a year | At 7.97p/kWh (cap now) | At ~10.08p/kWh (January estimate) |
|---|---|---|---|
| Cautious: 3%Small change (e.g. 70°C to 60°C), or a home that already ran fairly cool | 285 kWh | £23 a year | £29 a year |
| Middle: 6%In line with the heating industry's 6–8% estimate | 570 kWh | £45 a year | £57 a year |
| Best case: 9%Nesta's Salford test result for 80°C to 60°C | 855 kWh | £68 a year | £86 a year |
The sum: 9,500 kWh × 9% = 855 kWh saved. At October's capped gas rate of 7.97p per kWh (including 5% VAT), that's £68 a year. The January column scales the gas rate by the forecast rise in the cap, about 27%. It's our estimate, not an Ofgem figure, and shows the saving as if January's price lasted a full year.
For comparison, Nesta's own current estimate is £57 a year for an average home at the October–December 2026 cap, which sits in the middle of that table. It's not life-changing, but it's free, takes two minutes, and the saving repeats every winter. Octopus says 115,000 of its customers tried this tip in its Winter Workout scheme and 93% rated it useful.
Most of the saving lands in the coldest months, when the heating runs most. So the best time to do it is now, before January's higher rates arrive.
We earn £50 when you join through this link too. How we make money.
When to be careful, or leave it alone
Someone in the home is vulnerable to cold
Older people, babies, and anyone with a heart, lung or circulation condition need a warm home. EDF's guidance flags this too. A slower warm-up may not suit them. Change it gradually and keep checking the room temperature.
Small radiators or a draughty older house
Radiators sized for 80°C water give out less heat at 60°C. In a poorly insulated home the rooms may not keep up on the coldest days. Turn it back up 5°C if so. Turning it down in spring and autumn can still pay.
A hot water cylinder
Keep stored water at 60°C or above for Legionella control, as the HSE advises. If the same flow heats the cylinder, don't set it below what the cylinder needs.
Weather compensation or smart controls
Some boilers and thermostats already adjust the flow temperature automatically. If yours does, the settings may be managed for you. Check the manual before overriding them.
Old non-condensing boilers
Pre-2005 boilers without a condensing heat exchanger don't get the same efficiency gain, and some aren't designed to run cool. Ask an engineer first.
Anything behind a screwed-on cover
Never take the casing off a gas boiler. If the setting isn't on the outside, leave it for a Gas Safe registered engineer.
Why it matters more from January
Gas is what's pushing bills up this winter. Supplier forecasts put the January 2027 price cap at about £2,180 a year for a typical home, roughly 27% above October's £1,723. Ofgem confirms the real figure on 25 November. Every kWh of gas you don't burn is worth more once that lands.
Longer term, the same logic gets stronger. The Budget plans to scrap the gas standing charge from the end of 2027 and move its cost into the unit rate. A higher unit rate makes every efficiency saving, including this one, worth a little more.
Using less gas is one lever. The price you pay for it is the other. A fixed tariff locks your rates before January, and the appliance running cost calculator shows where the rest of your electricity goes. If you're weighing up a fix, our fix or variable guide works through the numbers.
Sources: Nesta: Money Saving Boiler Challenge · Nesta: UK households could save £1 billion (Oct 2022) · Nesta: Salford Energy House flow temperature testing (Oct 2022) · Nesta: Impact of boiler optimisation on gas use and comfort (Oct 2023) · HSE: Legionella in hot and cold water systems · Which?: Tips to reduce your heating bills · EDF: Lower the flow temperature on your combi boiler · Smart Energy GB: Boiler flow temperature · Octopus Energy: Energy saving tips · Octopus Energy: Winter Workout tips · Octopus Energy: Energy Helpers (HHIC 6–8% estimate) · Ofgem: Energy price cap. Figures last checked 12 November 2026.